Audiogram Maker and How to Read an Audiogram

Type in the numbers from a hearing test to draw a standard audiogram, then learn what it shows. One of our hearing tools.

Looking for a podcast "audiogram", the waveform video made for social media? This page is about hearing test charts, so a video editing app is what you need for that.

Last updated: November 9, 2026

This is a screening tool, not a medical test. Results depend on your headphones, volume and room.

Examples (each one is an example, not real data)

Import reads your latest saved result from the online hearing test on this device and shows it as relative values. No result yet? Take our free hearing screening.

Hearing levels (dB HL)

Type the softest level heard at each frequency, from −10 to 120 dB HL. The ↑ and ↓ keys change a value by 5. Leave a box empty if it was not tested. Use ⋯ to mark a value as masked or no response.

  • ORight air
  • XLeft air
  • △Right air, masked
  • □Left air, masked
  • <Right bone
  • >Left bone
  • [Right bone, masked
  • ]Left bone, masked
  • ↙↘No response (arrow)

Pattern notes

    Checks

      Options
      Classification
      Overlays
      Colors
      Details (optional)

      For example "Mum, 2026". Kept only with audiograms you save on this device, and printed on the PDF.

      Saved audiograms

        Audiograms you save on this device appear here.

        Everything you type stays in your browser. Nothing is uploaded.

        This tool draws and explains an audiogram; it is not a medical diagnosis. An audiologist interprets an audiogram together with your history, an ear examination, speech tests and middle-ear tests. Values from our online hearing test are relative, not dB HL, so no hearing-loss degree is shown for them.

        How to make your audiogram

        Your hearing test report usually has a table with the frequencies across the top, from 125 or 250 Hz up to 8,000 Hz, and a row of numbers for each ear. Copy each number into the matching box in the grid: the right ear goes on the first row and the left ear on the second. The chart updates as you type, and the arrow keys change a value by 5 dB.

        If your report includes bone conduction, turn on "Add bone conduction" and fill in those rows too; they cover 250 to 4,000 Hz. If the audiologist tested 750 or 1,500 Hz, turn on the extra columns. Where your report shows a masked result, or an arrow for no response, open the ⋯ menu in that box and tick Masked or No response.

        Then choose the ASHA or WHO classification and the overlays you want. Download the chart as a PNG, print it or save it as a PDF, or save it on this device to compare with later tests.

        How to read an audiogram

        The two axes

        Left to right is pitch. It starts with low sounds at 125 Hz, like a deep hum, and rises to high sounds at 8,000 Hz, like a bird's chirp. Top to bottom is loudness in dB HL, from very soft at the top to very loud at the bottom. Each mark is your threshold: the softest level at which you heard that pitch about half the time. Zero dB HL is not silence. It is the average threshold of young adults with normal hearing, which is why a mark at −10 dB HL is possible: that ear heard a little better than average.

        The symbols

        Audiograms use a standard set of symbols published by ASHA. Red marks the right ear and blue the left; on black-and-white copies, the shapes alone tell them apart.

        SymbolMeaning
        ORight ear, air conduction
        XLeft ear, air conduction
        △Right ear, air conduction, masked
        □Left ear, air conduction, masked
        <Right ear, bone conduction
        >Left ear, bone conduction
        [Right ear, bone conduction, masked
        ]Left ear, bone conduction, masked
        ↙ ↘No response at the audiometer's maximum (right, left)

        The air results of each ear are joined by a line. An arrow attached to a symbol means you did not hear that tone even at the loudest level the audiometer could play.

        Degree of hearing loss

        Two common systems turn the numbers into a word. ASHA uses the pure-tone average of 500, 1,000 and 2,000 Hz for each ear. WHO (2021) uses the average of 500, 1,000, 2,000 and 4,000 Hz in the better ear, because it was designed for counting hearing loss across whole populations.

        ASHA degrees of hearing loss
        ASHA degreePTA (dB HL)
        Normal−10 to 15
        Slight16 to 25
        Mild26 to 40
        Moderate41 to 55
        Moderately severe56 to 70
        Severe71 to 90
        Profound91 and above
        WHO 2021 grades of hearing loss
        WHO gradeBetter-ear average (dB HL)
        NormalUnder 20
        Mild20 to under 35
        Moderate35 to under 50
        Moderately severe50 to under 65
        Severe65 to under 80
        Profound80 to under 95
        Complete95 and above

        The degree is a summary. Two people with the same number can hear very differently, especially if one of them has a sharp loss at high pitches that the average hides.

        The speech banana and familiar sounds

        Most speech sounds sit in a curved, banana-shaped area of the audiogram, from about 250 to 6,000 Hz and about 20 to 60 dB HL. Vowels are low and loud, while soft high consonants such as "s", "f" and "th" sit toward the top right. Marks below the banana mean some speech sounds are missed, often those soft high consonants, which is why people with high-frequency loss feel that others mumble. The familiar-sounds overlay shows roughly where a whisper, normal conversation, a dog's bark, a lawn mower and a chainsaw fall. Treat it as a rough guide, because real sounds spread over many pitches.

        Common audiogram patterns

        These small charts are examples, not real data. They show the shapes audiologists see most often.

        Normal. All marks sit between −10 and 15 dB HL (ASHA) or below 20 dB HL (WHO), with both ears close together.
        Age-related sloping loss. Hearing gets gradually worse toward high pitches, usually similar in both ears. This is the most common pattern in older adults.
        Noise notch. A dip at 3,000 to 6,000 Hz, often deepest at 4,000 Hz, with some recovery at 8,000 Hz. It is typical after years of loud noise.
        Conductive loss. Air results are worse than bone results, and bone is near normal. Something in the outer or middle ear, such as earwax or fluid, is blocking sound.
        Sensorineural loss. Air and bone results drop together, with no gap. The problem is in the inner ear or the hearing nerve; age and noise are the most common causes.
        Mixed loss. Bone results show a loss and air results are worse still: a sensorineural and a conductive part together.
        Low-frequency rising loss. Worse at low pitches and better at high ones. It is less common, and is seen in some inner-ear conditions.

        Air conduction vs bone conduction

        Air conduction is tested through headphones or insert earphones. The sound travels through the whole ear: the ear canal, the eardrum and the tiny middle-ear bones, then the inner ear. Bone conduction uses a small vibrator pressed on the bone behind the ear. It gently vibrates the skull and reaches the inner ear directly, skipping the outer and middle ear.

        Comparing the two tells the audiologist where a problem is. If bone results are normal but air results are worse, the inner ear works and something before it is blocking sound. If both are worse by the same amount, the inner ear or the nerve is involved. A difference of more than 10 dB between them is called an air-bone gap.

        Masking means playing noise in the other ear during the test. Sound, especially bone-conducted sound, can cross the head, so masking stops the better ear from "helping" and makes sure the result belongs to the ear being tested.

        Pure-tone average and what the numbers mean

        The pure-tone average (PTA) is the mean of an ear's thresholds at a few key frequencies. A worked example: if your right ear's thresholds are 15 dB HL at 500 Hz, 25 dB HL at 1,000 Hz and 35 dB HL at 2,000 Hz, the PTA is (15 + 25 + 35) ÷ 3 = 25 dB HL, which is slight hearing loss on the ASHA scale. The WHO version adds 4,000 Hz: with 50 dB HL there, the 4-frequency average is (15 + 25 + 35 + 50) ÷ 4 = 31.25 dB HL, which is in the mild grade.

        The PTA is a useful summary and a good way to track change, but it can hide a lot. A sharp loss at 4,000 to 8,000 Hz barely moves a 3-frequency average, even though it makes many consonants hard to hear. That is why the full chart matters more than any single number.

        Online screening results vs a clinical audiogram

        A clinic audiometer is calibrated, so each tone has a known level in dB HL. A browser cannot know how loud your headphones or speakers are, so an online test cannot measure dB HL. What our online hearing test can show is the shape of your hearing across pitches and the difference between your ears. When you import a result from it, this tool switches to Relative mode: the scale becomes "Relative dB (not dB HL)", and the degree bands, pure-tone average, degree labels, speech banana and familiar sounds are hidden, because none of them can be worked out from relative values.

        If you don't have an audiogram yet, take our free hearing screening first. To check pitches above 8,000 Hz, find your highest audible frequency. If you have ringing in your ears, tinnitus pitch matching can help you describe it, since tinnitus often sits near the edge of a hearing loss.

        Questions to ask your audiologist

        • What type of hearing loss do I have, and what degree is it?
        • Is it the same in both ears? If not, does the difference need more tests?
        • Would hearing aids or other devices help me now?
        • How often should I have my hearing retested?
        • What can I do to protect the hearing I have?

        Ask for a copy of your audiogram after every test, so you can plot it here and compare results over time.

        Audiogram FAQ

        What does a normal audiogram look like?

        All the marks for both ears sit near the top of the chart, between −10 and 15 dB HL on the ASHA scale or below 20 dB HL on the WHO scale, at every frequency from 250 to 8,000 Hz. The two ears are usually within about 10 dB of each other, and air and bone results line up. A small dip at a single frequency is common and often not significant.

        Why is the loudness scale upside down?

        Audiograms put the softest sounds at the top so that better hearing sits higher on the chart and hearing loss "drops" down it. The numbers grow toward the bottom because they show how loud a sound must be before you hear it. So a mark at 60 dB HL, low on the chart, means you only hear that pitch when it is fairly loud.

        What does dB HL mean?

        dB HL stands for decibels hearing level. Zero dB HL is the average softest level that young adults with normal hearing can detect at each frequency, set by international standards. Because normal ears are less sensitive to low pitches, 0 dB HL at 250 Hz is about 25 dB of actual sound pressure on standard audiometer earphones, but only about 7 dB at 1,000 Hz. The scale removes that difference.

        What do the arrows on an audiogram mean?

        An arrow attached to a symbol means "no response": you did not hear the tone even at the loudest level the audiometer could play at that frequency. The symbol is drawn at that maximum level and the arrow points down, toward the right for the left ear and toward the left for the right ear. Your real threshold is somewhere below that point on the chart.

        Can I make an audiogram from an online hearing test?

        You can import a result from our online hearing test, and the chart will show its shape and the difference between your ears. But a browser cannot measure dB HL, because it does not know how loud your headphones are, so the chart switches to "relative dB" and shows no degree of hearing loss. For a true audiogram, you need a test with a calibrated audiometer.

        Why does my audiogram stop at 8,000 Hz?

        Standard clinical hearing tests cover 250 to 8,000 Hz, sometimes from 125 Hz, because those frequencies matter most for understanding speech. Higher frequencies, from about 9,000 to 20,000 Hz, can be tested with special equipment called extended high-frequency audiometry. It is used for some monitoring, for example during medicines that can affect hearing. This maker plots the standard range.

        Is my audiogram data uploaded anywhere?

        No. Everything you type is processed in your browser and saved only if you press "Save on this device", which keeps it in local storage on that device. The PNG, PDF and CSV files are created on your device too. If you make a share link, the values are in the part of the link after the "#", which browsers never send to our server.